Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
3.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37737699

RESUMO

We describe an inertial rotation sensor with a 30-cm cylindrical proof-mass suspended from a pair of 14 µm thick BeCu flexures. The angle between the proof-mass and support structure is measured with a pair of homodyne interferometers, which achieve a noise level of ∼5prad/Hz. The sensor is entirely made of vacuum compatible materials, and the center of mass can be adjusted remotely.

4.
Rev Sci Instrum ; 94(5)2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37191465

RESUMO

Control noise is a limiting factor in the low-frequency performance of the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO). In this paper, we model the effects of using new sensors called Homodyne Quadrature Interferometers (HoQIs) to control the suspension resonances. We show that if we were to use HoQIs, instead of the standard shadow sensors, we could suppress resonance peaks up to tenfold more while simultaneously reducing the noise injected by the damping system. Through a cascade of effects, this will reduce the resonant cross-coupling of the suspensions, allow for improved stability for feed-forward control, and result in improved sensitivity of the detectors in the 10-20 Hz band. This analysis shows that improved local sensors, such as HoQIs, should be used in current and future detectors to improve low-frequency performance.

5.
Rev Sci Instrum ; 94(1): 014502, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725558

RESUMO

Advanced Laser Interferometer Gravitational-wave Observatory (LIGO A+) is a major upgrade to LIGO-the Laser Interferometer Gravitational-wave Observatory. For the A+ project, we have developed, produced, and characterized sensors and electronics to interrogate new optical suspensions designed to isolate optics from vibrations. The central element is a displacement sensor with an integrated electromagnetic actuator known as a BOSEM (Birmingham Optical Sensor and ElectroMagnetic actuator) and its readout and drive electronics required to integrate them into LIGO's control and data system. In this paper, we report on the improvements to the sensors and the testing procedures undertaken to meet the enhanced performance requirements set out by the A+ upgrade to the detectors. The best devices reach a noise level of 4.5 ×10-11m/Hz at a measurement frequency of 1 Hz, an improvement of 6.7 times over standard devices.

6.
Opt Express ; 28(7): 10253-10269, 2020 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-32225614

RESUMO

An accurate readout of low-power optical higher-order spatial modes is of increasing importance to the precision metrology community. Mode sensors are used to prevent mode mismatches from degrading quantum and thermal noise mitigation strategies. Direct mode analysis sensors (MODAN) are a promising technology for real-time monitoring of arbitrary higher-order modes. We demonstrate MODAN with photo-diode readout to mitigate the typically low dynamic range of CCDs. We look for asymmetries in the response of our sensor to break degeneracies in the relative alignment of the MODAN and photo-diode and consequently improve the dynamic range of the mode sensor. We provide a tolerance analysis and show methodology that can be applied for sensors beyond first order spatial modes.

7.
Rev Sci Instrum ; 88(11): 115008, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29195374

RESUMO

In this paper, the sensor noise of two geophone configurations (L-22D and L-4C geophones from Sercel with custom built amplifiers) was measured by performing two huddle tests. It is shown that the accuracy of the results can be significantly improved by performing the huddle test in a seismically quiet environment and by using a large number of reference sensors to remove the seismic foreground signal from the data. Using these two techniques, the measured sensor noise of the two geophone configurations matched the calculated predictions remarkably well in the bandwidth of interest (0.01 Hz-100 Hz). Low noise operational amplifiers OPA188 were utilized to amplify the L-4C geophone to give a sensor that was characterized to be near Johnson noise limited in the bandwidth of interest with a noise value of 10-11 m/Hz at 1 Hz.

8.
Opt Express ; 21(16): 19047-60, 2013 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-23938820

RESUMO

Squeezed states of light are an important tool for optical measurements below the shot noise limit and for optical realizations of quantum information systems. Recently, squeezed vacuum states were deployed to enhance the shot noise limited performance of gravitational wave detectors. In most practical implementations of squeezing enhancement, relative fluctuations between the squeezed quadrature angle and the measured quadrature (sometimes called squeezing angle jitter or phase noise) are one limit to the noise reduction that can be achieved. We present calculations of several effects that lead to quadrature fluctuations, and use these estimates to account for the observed quadrature fluctuations in a LIGO gravitational wave detector. We discuss the implications of this work for quantum enhanced advanced detectors and even more sensitive third generation detectors.

9.
Phys Rev Lett ; 100(1): 010801, 2008 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-18232749

RESUMO

A series of recent articles have presented results demonstrating optical cooling of macroscopic objects, highlighting the importance of this phenomenon for investigations of macroscopic quantum mechanics and its implications for thermal noise in gravitational wave detectors. In this Letter, we present a measurement of the off-resonance suspension thermal noise of a 1 g oscillator, and we show that it can be cooled to just 70 mK. The cooling is achieved by using a servo to impose a phase delay between oscillator motion and optical force. A model is developed to show how optical rigidity and optical cooling can be interchangeable using this technique.

10.
Phys Rev Lett ; 92(16): 161102, 2004 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-15169214

RESUMO

We present results that are a classical analog to quantum noise cancellation. It is possible to breach the standard quantum limit in an interferometer by the use of squeezing to correlate orthogonal quadratures of quantum noise, causing their effects on the resulting sensitivity to cancel. A laser beam incident on a Fabry-Perot cavity was imprinted with classical, correlated noise in the same quadratures that cause shot noise and radiation pressure noise. Couplings between these quadratures due to a movable mirror, sensitive to radiation pressure, cause the excess classical noise to cancel. This cancellation was shown to improve the signal to noise ratio of an injected signal by approximately a factor of 10.